Precision Nitrogen Control for Dry Cabinets

Advanced NC-5R System Optimizes RH/O2 Levels, Ensures Compliance, and Maximizes Savings for Sensitive Component Storage

Designed to precisely manage dry air filling within a cabinet, achieving desired relative humidity or optional oxygen levels for optimal component protection and significant gas savings

Digital Nitrogen Controller (NC-5R)

Product Description:

The Dr.Storage Digital Nitrogen Controller (NC-5R) is designed to precisely manage dry air filling within a cabinet to achieve desired relative humidity or optional oxygen levels. Unlike traditional nitrogen cabinets that continuously fill dry air, the NC-5R can save 30-60% of dry air consumption. In the event of a power outage, the controller automatically opens to continuously fill dry air, protecting the cabinet’s contents. This controller is compatible with nitrogen, CO2, or inert gases as the dry air source.
Key features include energy savings from non-continuous dry air filling, easy upgradeability for existing nitrogen cabinets, and robust data recording capabilities. The data recording function, viewable in graphs, allows users to monitor historical fluctuations of relative humidity, optional oxygen levels, and temperature, aiding in J-STD-033D compliance and calculating Moisture Sensitive Device (MSD) floor life. A unique calibration reminding function flashes a decimal point on the panel after 365 days, ensuring sensor accuracy and ISO compliance. The NC-5R also features an alarm setting with flash and buzz options, activated when humidity, optional oxygen levels, or temperature exceed a set upper limit, with adjustable delay times.

Specifications include an operation range of:

  • 0.1−65∘C, 0.1-80%RH, and an optional O2 level of 0-25%. Sensor precision is
  • ±1.0∘C for temperature and ±2.0%RH for humidity, with optional O2 sensor precision of <2% FS/0.1 mbar. Resolutions are
  • 0.1∘C for temperature, 0.1%RH for humidity, and 0.01%/0.1 mbar for oxygen (optional). The unit measures W250

D210H92mm and weighs 3.8kgs. It includes an adjustable nitrogen flow meter (1-25L/min) and operates on 110V/230V power with a maximum consumption of 10W (average 5Wh). Optional accessories include the GT-05 Data Logger, a flow meter, an external alarm tower, an O2 sensor module, and door switches.

Key Features

Operation Range:

  • Temperature: 0.1−65∘C
  • Humidity: 0.1~80%RH
  • O2 level: 0-25% (option)

Precision:

  • Temperature Sensor: ±1.0∘C
  • Humidity Sensor: ±2.0%RH
  • O2 Sensor: <2% FS/0.1 mbar (option)

Resolution:

  • Temperature: 0.1∘C
  • Humidity: 0.1%RH
  • Oxygen: 0.01%/0.1 mbar (option)

    Dimension: W250D210H92mm
    Nitrogen Flow Meter: 1~25L/min (adjustable)
    Weight: 3.8kgs

    Power: 110V/230V (select voltage in advance)
    Power Consumption: Max. 10W; Ave. 5Wh (at 1%~80%RH)

    Fine resolution: 0.1℃ (temperature), 0.1%RH (humidity)
    Display refresh: 45 seconds
    Excellent Stability: ≦0.25 (%RH/yr), ≦0.03 (°C/yr)
    Compact dimensions: W25xL68xH45mm

     

      Optional Accessories

      GT-05 Data Logger

      Memory Capacity 40,000 Records.

      External Tower Alarm

      RH Alarm Activates if Preset Value is Exceeded.

      Nitrogen Flow Sensor

      Flow Meter Specs: 1-25L/min (adjustable)

      Cabinet Door Switches

      Shuts Off N2 When Door is Opened.

      O2 Sensor Module

      Oxygen Level Detection
      (0% ~ 25%)

      Contact Us for a Quote

      Contact SMT Dry Boxes for expert support and guidance on humidity control and our range of dry storage solutions. Whether you have questions about product selection, technical specifications, or require assistance with an existing system, our knowledgeable team is here to help. We are committed to providing prompt and helpful support to ensure your satisfaction.